LCC Architecture: Types and Components of a Marina 2

Marina Design and Architecture
THE MARINA 2
COMPONENTS (continued)
Locks: often have more than 1 compartment; should maintain constant water level on 1 side, other side varying with tide; capacity decided by peak use; waiting pontoons either side lock recommended.
Pontoon design: often used to carry services and to support lighting units, lockers, refuse collection points, fire fighting devices; service bollards often provided: boats/bollard 2-6; sewage collection points for boats recommended either as holding tanks or as outlets connected with vacuum sewage system leading to onshore network. Min w main access pontoons 2000 with fingers^ 500 wide; if total pier I over 100, 2500 w more appropriate; min w floating pontoon 2500.
Pontoon types: fixed: for non-tidal marinas; fixed deck Continue reading →